{"product_id":"marsh-ensign-standard-16pe","title":"Marsh Ensign: Standard Sewage Treatment Plant - 16PE","description":"\u003cp\u003eMarsh Ensign: Standard sewage treatment plants are widely regarded as the most efficient, reliable and economical domestic systems on the market.\u003c\/p\u003e\n\u003cp\u003eThe standard Ensign has been adapted to improve reliability and the Ensign:Ultra now brings unique enhancements to further improve noise level, treatment efficiency and final effluent quality.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBenefits;\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eNo moving parts\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eLow running and maintenance costs\u003c\/li\u003e\n\u003cli\u003eFaster and safer to install due to lifting eye\u003c\/li\u003e\n\u003cli\u003eTested and certified to BSEN12566-3\u003c\/li\u003e\n\u003cli\u003e50-year design life\u003c\/li\u003e\n\u003cli\u003e25-year structural guarantee\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0039\/1456\/3682\/files\/Ensign_Features_480x480.png?v=1611499745\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e1. Inlet with ‘Forsheda seal’\u003c\/span\u003e\u003cbr\u003eForsheda seal provides flexibility in the joint for easier installation.\u003cbr\u003eOptional risers to increase invert depth are available.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2. Primary settlement chamber\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e3. Aeration chamber\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e4. Advanced compressor with alarm (Ensign:Ultra units only)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eNear silent compressor ensures minimal running, maintenance and servicing costs. Integral alarm detects low pressure in air line. (Regular low-energy compressor on Ensign:Standard models).\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e5. Compressor housing – internal or external options available\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe compressor can be housed internally or externally with no difference in cost.\u003cbr\u003eExternal recommended to increase compressor life, and supplied as standard on 4PE, shallow and pumped outlet versions.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e6. RCD\/Electrical connection (Ensign:Ultra units only)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe RCD box provides easier installation and provides a higher degree of safety. (Regular plug\/socket connection on Ensign:Standard models).\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e7. PVC pressure pipe\/diffuser(s)\u003c\/span\u003e\u003cbr\u003eProvides a protective conduit for the air diffuser line. Can be easily removed for maintenance and cleaning.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e8. Bio-media\u003c\/span\u003e\u003cbr\u003eHigh specification bio-media (310m3 per m2) and membrane diffusers ensure even circulation to eliminate ‘dead spots’. The bio-media is contained by a stainless steel securing mesh to ensure no migration during handling or potential flooding.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e9. Stainless steel mesh\u003c\/span\u003e\u003cbr\u003eRetains media in aeration chamber during transportation and handling, and in the event of flooding.10. Final settlement chamber\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e10. Final Settlement Chamber\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e11. 32mm sludge return\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e Larger diameter sludge return prevents the possibility of blockages and improves system circulation. Provides higher effluent quality whilst balancing flow over a 24 hour period or periods of intermittent use.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e12. Unique Polylok tertiary filter (Ensign:Ultra units only)\u003c\/span\u003e\u003cbr\u003e The Polylok tertiary filter reduces suspended solids and BOD by a further 40% helping to extend drainage field life\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e13. Outlet with ‘Forsheda seal'\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e Forsheda seal provides flexibility in the joint for easier installation.\u003cbr\u003e Optional pumped outlets are available.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e14. Impermeable lid\u003c\/span\u003e\u003cbr\u003e Heavy duty lid\/frame improves strength and durability whilst blending into the surrounding environment. (Regular lid on Ensign:Standard models).\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e15. Integral lifting eyes\u003c\/span\u003e\u003cbr\u003e For safe and secure on-site handling.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e16. Stabilising feet\u003c\/span\u003e\u003cbr\u003e Stabilising feet prevents the tank from rolling and allows safe and steady transportation and installation.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e17. Unique ‘keying-in’ lip\u003c\/span\u003e\u003cbr\u003e Assists anchoring into granular or concrete surrounds.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eSpecification\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable height=\"160\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePopulation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLength (mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2860\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWidth (mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1912\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHeight (mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2284\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInlet Invert (mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e720\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutlet Invert (mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInlet and Outlet Pipe (mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e110\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Marsh Industries","offers":[{"title":"No \/ No \/ No","offer_id":58171090764125,"sku":null,"price":2999.99,"currency_code":"GBP","in_stock":true},{"title":"No \/ No \/ Yes","offer_id":58651921678685,"sku":null,"price":3494.99,"currency_code":"GBP","in_stock":true},{"title":"No \/ Yes \/ No","offer_id":58651921711453,"sku":null,"price":3142.79,"currency_code":"GBP","in_stock":true},{"title":"No \/ Yes \/ Yes","offer_id":58651921744221,"sku":null,"price":3637.79,"currency_code":"GBP","in_stock":true},{"title":"Yes \/ No \/ No","offer_id":58651921776989,"sku":null,"price":3094.99,"currency_code":"GBP","in_stock":true},{"title":"Yes \/ No \/ Yes","offer_id":58651921809757,"sku":null,"price":3589.99,"currency_code":"GBP","in_stock":true},{"title":"Yes \/ Yes \/ No","offer_id":58651921842525,"sku":null,"price":3237.79,"currency_code":"GBP","in_stock":true},{"title":"Yes \/ Yes \/ Yes","offer_id":58651921875293,"sku":null,"price":3732.79,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0963\/5020\/8349\/files\/ensign12_2048x2048-400x400.jpg?v=1754404399","url":"https:\/\/www.tdgsolutions.uk\/products\/marsh-ensign-standard-16pe","provider":"TDG Solutions LTD","version":"1.0","type":"link"}